Add to Cart
dc to ac power inverter charge combi 1kw 12VDC20A 230VAC/50HZ cs1020l
Energier essential bi-directional inverter was especially designed for Power Shedding application, of which providing true sine-wave inverter, multistage battery charging and a transfer switch in together. It can be connected to either grid or generator to compose power system for the most demanding mobile, off grid and power backup application.
Features,
-Designed for tropical region with working temperature up to 60℃
-Compatible with majority of cheap generators in the market
-Can be applied for power backup and solar hybrid system
-Equalization charging program was available
Connecting the cable
Please make sure Energier essential bi-directional inverter is turned off before connection. Otherwise, high voltage could be present.
Please double check battery voltage match the model you are going to installed, the wrong battery could destroy equipment and is out of warranty.
Please double confirm the polarity of DC input. Reverse polarity could cause permanent damage on equipment and it is out of warranty.
Specification
Model No. | 12Vdc | CS0625L | CS1040L | CS2080L | ||||||
24Vdc | CS0615M | CS1020M | CS2040M | CS3060M | CS4080M | |||||
48Vdc | CS3030S | CS4040S | ||||||||
INVERTER | ||||||||||
Nominal Voltage | 12Vdc, 24Vdc, 48Vdc | |||||||||
power 30mins @25℃ (W) | 600 | 1000 | 2000 | 3000 | 4000 | |||||
Cont.power@25℃ (W) | 600 | 1000 | 1800 | 2500 | 3600 | |||||
Cont.power@40℃ (W) | 600 | 1000 | 1500 | 2000 | 3000 | |||||
Cos φ | 0.9-1 | |||||||||
Surge | 300% | |||||||||
Output voltage【1】 | 230VAC or 110VAC ± 2% | 230VAC ± 2% | ||||||||
Output frequency | 50Hz or 60Hz ± 0.1% | |||||||||
Efficiency (MAX.) | 12Vdc | 88% | ||||||||
24Vdc | 88% | |||||||||
48Vdc | 92% | |||||||||
Bypass | UPS mode | 184VAC-264VAC/92VAC-132VAC | 184VAC-264VAC | |||||||
GEN mode | 160VAC-280VAC/80VAC-140VAC | 160VAC-280VAC | ||||||||
Crest factor | 3:1 | |||||||||
THD | <3% | |||||||||
Zero load power | 17 | 22 | 27 | 36 | 62 | |||||
Zero load power (power save mode) | 4 | 5 | 7 | 9 | 15 | |||||
Output circuit breaker | 5A | 10A | 15A | 30A | 30A | |||||
Overheat protection | auto disconnect | |||||||||
Overload protection | auto disconnect | |||||||||
shortcut protection | auto disconnect | |||||||||
Charger | ||||||||||
Nominal Output Voltage | 12Vdc, 24Vdc, 48Vdc | |||||||||
Max Output current (A) - adjustable | 25/15 | 40/20 | 80/40 | 60/30 | 80/40 | |||||
AC Input range | UPS mode | 184VAC - 264VAC/92VAC-132VAC | 184VAC - 264VAC | |||||||
GEN mode | 160VAC - 280VAC/80VAC-140VAC | 160VAC - 280VAC | ||||||||
Battery types | AGM / GEL / LFP / Flooded | |||||||||
Absorption time | variable | |||||||||
Temperature compensation | -4mV/℃/cell | |||||||||
Charger circuit breaker | 5A | 10A | 15A | 30A | 30A | |||||
Other Data | ||||||||||
Transfer time | UPS mode | 15ms | ||||||||
GEN mode | 2s | |||||||||
Transfer switch | 40A | |||||||||
Battery connector | M8 x 2 | |||||||||
AC connector | Terminal block (M3 screw) | |||||||||
Mechanical Data | ||||||||||
Enclosure | Steel with powder paint | |||||||||
Dimension (mm) | 444x186x135 | 512x216x176 | ||||||||
Net Weight (kgs) | 9.5 | 14 | 16 | 18.5 | 22.5 | |||||
Cooling | Forced fan | |||||||||
Protection | IP20 | |||||||||
Standard | ||||||||||
Safety | EN60950-1 | |||||||||
EMC | EN55022,EN55024 | |||||||||
【1】Output voltage: 220VAC/60Hz for Philippines |