Power Backup Inverter 600W 12VDC25A 230VAC/50HZ Bi-directional Inverter
Energier Essential bi-directional inverter can be used in multiple applications.You can use it
to compose power backup system. Or, with a quick setting,you can compose a simple solar
hybrid system either with grid or diesel-generators.
Features,
-Bi directional inverter with pure sine wave output
-Can be applied for power backup and solar hybrid system
-Optional CM was available for automatic generator start
-Optional SNMP card for remote internet access
-High performance designed for all kinds of home appliances
-Designed for tropical region with working temperature up to 60℃
-automatic temperature compensation -Equalization charging program was available
-TBB premium II multi stage charging algorithm with built in
-Compatible with majority of cheap generators in the market
-Designed to work with weak grid
Installations
Basically, Energier essential bi-directional inverter could be installed either vertically on wall or horizontally on floor,
Step 1-4.
Specification
Model No. | 12Vdc | CS0625L | CS1040L | CS2080L | ||||||
24Vdc | CS0615M | CS1020M | CS2040M | CS3060M | CS4080M | |||||
48Vdc | CS3030S | CS4040S | ||||||||
INVERTER | ||||||||||
Nominal Voltage | 12Vdc, 24Vdc, 48Vdc | |||||||||
power 30mins @25℃ (W) | 600 | 1000 | 2000 | 3000 | 4000 | |||||
Cont.power@25℃ (W) | 600 | 1000 | 1800 | 2500 | 3600 | |||||
Cont.power@40℃ (W) | 600 | 1000 | 1500 | 2000 | 3000 | |||||
Cos φ | 0.9-1 | |||||||||
Surge | 300% | |||||||||
Output voltage【1】 | 230VAC or 110VAC ± 2% | 230VAC ± 2% | ||||||||
Output frequency | 50Hz or 60Hz ± 0.1% | |||||||||
Efficiency (MAX.) | 12Vdc | 88% | ||||||||
24Vdc | 88% | |||||||||
48Vdc | 92% | |||||||||
Bypass | UPS mode | 184VAC-264VAC/92VAC-132VAC | 184VAC-264VAC | |||||||
GEN mode | 160VAC-280VAC/80VAC-140VAC | 160VAC-280VAC | ||||||||
Crest factor | 3:1 | |||||||||
THD | <3% | |||||||||
Zero load power | 17 | 22 | 27 | 36 | 62 | |||||
Zero load power (power save mode) | 4 | 5 | 7 | 9 | 15 | |||||
Output circuit breaker | 5A | 10A | 15A | 30A | 30A | |||||
Overheat protection | auto disconnect | |||||||||
Overload protection | auto disconnect | |||||||||
shortcut protection | auto disconnect | |||||||||
Charger | ||||||||||
Nominal Output Voltage | 12Vdc, 24Vdc, 48Vdc | |||||||||
Max Output current (A) - adjustable | 25/15 | 40/20 | 80/40 | 60/30 | 80/40 | |||||
AC Input range | UPS mode | 184VAC - 264VAC/92VAC-132VAC | 184VAC - 264VAC | |||||||
GEN mode | 160VAC - 280VAC/80VAC-140VAC | 160VAC - 280VAC | ||||||||
Battery types | AGM / GEL / LFP / Flooded | |||||||||
Absorption time | variable | |||||||||
Temperature compensation | -4mV/℃/cell | |||||||||
Charger circuit breaker | 5A | 10A | 15A | 30A | 30A | |||||
Other Data | ||||||||||
Transfer time | UPS mode | 15ms | ||||||||
GEN mode | 2s | |||||||||
Transfer switch | 40A | |||||||||
Battery connector | M8 x 2 | |||||||||
AC connector | Terminal block (M3 screw) | |||||||||
Mechanical Data | ||||||||||
Enclosure | Steel with powder paint | |||||||||
Dimension (mm) | 444x186x135 | 512x216x176 | ||||||||
Net Weight (kgs) | 9.5 | 14 | 16 | 18.5 | 22.5 | |||||
Cooling | Forced fan | |||||||||
Protection | IP20 | |||||||||
Standard | ||||||||||
Safety | EN60950-1 | |||||||||
EMC | EN55022,EN55024 | |||||||||
【1】Output voltage: 220VAC/60Hz for Philippines |