Add to Cart
TBB TP600 series inverter could achieve a compact size of maximized power density. Here are the Features;
TP600-1U standalone inverter features an integrated utility bypass. With a dip switch, the inverter can be set into AC priority mode, of which power is always connected to the AC utility line and will switch to inverter power line when AC utility fails with transfer time less than 8ms.
The performance of TP600-1U of inverter is at top of the market with peak efficiency up to 90% and small harmonics on DC side and it can be interfaced with RS232 and RS485.
Standby | Power off with AC input connected |
AC mode | AC priority mode |
Inverter mode | DC priority mode |
Notice | abnormal but did not affect operation |
Caution | abnormal but without entering into protection, issue need to be solved |
Warning | Serious fault detected, need to be solved immediately |
Fault | Inverter stop working, fault need be solved immediately |
Voltage setting range. (24VDC model as the sample,)
Voltage point | Default value | Setting range | Comments |
Low voltage protection(DC0) | 20V | 20~22V | |
Low voltage warning (DC2) | 22V | 22~24V | DC2 >= DC0 + 1V |
Low voltage recover(DC3) | 23V | 23~25V | DC3 >= DC2 + 1V |
DC low shutdown, second power on voltage (DC4) | 24V | 24~26V | |
High voltage recover(DC5) | 29V | 27~29V | DC5 <= DC6 - 1V |
High voltage protection(DC6) | 30V | 28~30V |
Led Shows
Specifications
TP600M and TP600S (24VDC/48VDC models)
Model | TP605 | TP610 |
Electrical | ||
DC input | 24Vdc or 48Vdc | 48Vdc |
Dc input range | .-17% ~ +25% | |
AC Input | ||
AC input | 230Vac or 110Vac (-25%~+20%) | 230Vac (-25%~+20%) |
Frequency range | ±10% | |
Output power | 500va | 1kva |
Wave form | Pure sine wave | |
Power factor | 0.8 | |
Norminal output voltage | 230Vac or 110Vac | 230Vac |
Voltage variation | Max ± 2% | |
Output frequency | 50/60Hz ± 0.1Hz | |
Efficiency | Max 88% | |
THD | <3% liner load | |
<5% non-liner load | ||
Crest factor | .3:1 | |
Overload | 125% 10secs | |
110% 10mins | ||
Transfer time | 5-8ms | |
Dynamic response time | < 30ms | |
LVD | 20Vdc or 40Vdc | 40Vdc |
Display & Communication | ||
LED indicator | Working mode, Fault info | |
Communication Interface | RS232 and RS485 | |
4xDry contact | ||
Safety & Enviroment | ||
Operating Temp. | Full load, <-20℃> - 40℃ | |
Derating using, 40℃ - 60℃ | ||
Isolation | 1500Vrms | |
Mechanical | ||
Dimension (WxH) | 19"1U | |
Depth | 319mm | |
Weight | 4.0kgs/4.5kgs | |
Cooling | forced fan with thermal control | |
Enclosure | IP20 | |
Standard | ||
LVD | EN60950-1 | |
EMC | EN55022 |