Add to Cart
TBB TP600 series inverter could achieve a compact size of maximized power density.
Combined with modern semiconductors and a patent pending control algorithm, TP600-1U inverter could achieve a compact size within the 19”1U height.
The team have the ability to choose from which input the load will be fed. In the case where the load is fed through the AC input, the equipment must have a filter against electromagnetic interference in order to improve the output waveform.
TP600-1U standalone inverter features an integrated utility bypass. With a dip switch, the inverter can be set into AC priority mode, of which power is always connected to the AC utility line and will switch to inverter power line when AC utility fails with transfer time less than 8ms.
Here are the Features;
- 19”1U or 19”2U
- High Frequency standby design with
- Transfer time 5-8ms
- Working mode selectable (AC priority or DC priority)
- High Frequency design
- DC/AC isolation improving system security
- System parameters programmable
- Complete protection
- Thermal controlled fan
- RS232 or RS485 communication port and Dry point
- Voltage adjustable 230Vac (200-240) or 110Vac (100-120)
- Front panel connection version available
LED shows
Specifications
TP600M and TP600S (24VDC/48VDC models)
Model | TP605 | TP610 |
Electrical | ||
DC input | 24Vdc or 48Vdc | 48Vdc |
Dc input range | .-17% ~ +25% | |
AC Input | ||
AC input | 230Vac or 110Vac (-25%~+20%) | 230Vac (-25%~+20%) |
Frequency range | ±10% | |
Output power | 500va | 1kva |
Wave form | Pure sine wave | |
Power factor | 0.8 | |
Norminal output voltage | 230Vac or 110Vac | 230Vac |
Voltage variation | Max ± 2% | |
Output frequency | 50/60Hz ± 0.1Hz | |
Efficiency | Max 88% | |
THD | <3% liner load | |
<5% non-liner load | ||
Crest factor | .3:1 | |
Overload | 125% 10secs | |
110% 10mins | ||
Transfer time | 5-8ms | |
Dynamic response time | < 30ms | |
LVD | 20Vdc or 40Vdc | 40Vdc |
Display & Communication | ||
LED indicator | Working mode, Fault info | |
Communication Interface | RS232 and RS485 | |
4xDry contact | ||
Safety & Enviroment | ||
Operating Temp. | Full load, <-20℃> - 40℃ | |
Derating using, 40℃ - 60℃ | ||
Isolation | 1500Vrms | |
Mechanical | ||
Dimension (WxH) | 19"1U | |
Depth | 319mm | |
Weight | 4.0kgs/4.5kgs | |
Cooling | forced fan with thermal control | |
Enclosure | IP20 | |
Standard | ||
LVD | EN60950-1 | |
EMC | EN55022 |
TP600D and TP600E (110VDC/220VDC models)
Model | TP605 | TP610 |
Electrical | ||
DC input | 110Vdc or 220Vdc | |
Dc input range | .-17% ~ +25% | |
AC Input | ||
AC input | 230Vac or 110Vac (-25%~+20%) | 230Vac (-25%~+20%) |
Frequency range | ±10% | |
Output power | 500va | 1kva |
Wave form | Pure sine wave | |
Power factor | 0.8 | |
Norminal output voltage | 230Vac or 110Vac | 230Vac |
Voltage variation | Max ± 2% | |
Output frequency | 50/60Hz ± 0.1Hz | |
Efficiency | Max 90% | |
THD | <3% liner load | |
<5% non-liner load | ||
Crest factor | .3:1 | |
Overload | 125% 60secs | |
110% 10mins | ||
Transfer time | 5-8ms | |
Dynamic response time | < 30ms | |
LVD | 91.5Vdc or 183Vdc | |
Display & Communication | ||
LED indicator | Working mode, Fault info | |
Communication Interface | RS232 and RS485 | |
4xDry contact | ||
Safety & Enviroment | ||
Operating Temp. | Full load, <-20℃> - 40℃ | |
Derating using, 40℃ - 60℃ | ||
Isolation | 2000Vrms | |
Mechanical | ||
Dimension (WxH) | 19"1U | |
Depth | 319mm | |
Weight | 4.0kgs/4.5kgs | |
Cooling | forced fan with thermal control | |
Enclosure | IP20 | |
Standard | ||
LVD | EN60950-1 | |
EMC | EN55022 |